Outfitted with rapid-response MSA XCell® sensors, the ALTAIR 4XR Gas Detector is the toughest 4-gas monitor on the market and is backed by a 4-year warranty.

Rugged:

Survives 25 drops from 4 feet (1.2 meters) (MIL-STD-810G 516.6 Transit Drop 3rd Party Certified)

Can survive an incidental 25-foot (7.5-m) drop onto concrete

Operating temperature range: -40°F to +140°F (-40°C to +60°C)

 

Reliable:

Sense gas 2 times faster than the industry average with our XCell sensors

4-year instrument & sensor warranty

Confirm compliance quickly with the Bump LED & on-screen checkmark

Bump and calibrate with 1/2 the test gas and in 1/2 the time vs. industry average

Bump and calibrate at a specified "Time of Day" with your MSA GALAXY® GX2 Automated Test System

MotionAlert option tells others that user has become immobile

User-activated InstantAlert notifies others of a potentially dangerous situation

 

OPTIONS:

Sensor Options

1. Combustible (LEL)

2. Oxygen

3. Toxic

a. CO / H2S

b. CO (H2-Resistant) / H2S

c. CO / H2S-LC

d. CO / NO2

e. SO2 / H2S-LC

 

ALTAIR® 4XR User Guide: Technical Data

Technical Data

Weight

7.9 oz./224 g (device with battery and clip)

Dimensions (L x W x H)

4.4 x 3.00 x 1.37 inches/112 x 76 x 33 mm
– without fastening clip

Alarms

Four gas alarm LEDs, a charge status LED, an audible alarm and a vibrating alarm

Volume of audible alarm

95 dBA at 30 cm typical

Display

LCD display  

Battery type

20 hours at 25 °C (77 °F)                                              Device run time is reduced nominally by 10% with Bluetooth enabled and nominally by 15% with the Backlight configured to always on. If both Bluetooth and the backlight are on the nominal runtime reduction will be 25%.

Charging time

£ 4 hours                                                         The maximum safe area charging voltage Um = 6.7 VDC

Warm up time

2 min

Temperature range

14 to 104 °F (-10 to 40 °C) Normal operating range                       -40 to 140 °F (-40 to 60 °C) Extended operating range                      50 to 95 °F (10 to 35 °C) While charging battery                         -40 to +140 °F (-40 to 60 °C) Intrinsic safety                          ambient temperature range (ATEX, IEC)                                -40 to +129 °F (-40 to 54 °C) Intrinsic safety ambient temperature range (CSA, ETL)

Humidity range

15 % – 90 % relative humidity, non-condensing,                         5 % – 95 % RH intermittent

Atmospheric pressure range

800 to 1200 mbar

Ingress  protection

IP 68 (2 meters for 45 minutes)

Measuring
methods

Combustible gases: Catalytic sensor                               Oxygen: Electrochemical sensor                                     Toxic gases: Electrochemical sensor

 

 

 

 

Combustible

O2

CO

H2S

Measuring range

0-100% LEL    0-5.00% Vol.CH4

0-30% Vol.

0-1999 ppm 0-1999 mg/m3

0-200 ppm  0-284 mg/m³

H2S-LC

NO2

CO-H2

SO2

0-100 ppm

0-50 ppm

0-1999 ppm

0-20 ppm

 